honeywell space heater won't turn on

If your Honeywell thermostat wont turn on heat, here are some reasons this might be happening: That said, lets look at how to troubleshoot this issue. Sun City Mechanical is your trusted source for heating system repairs in Buckeye. WEAK HEAT (WARM) - Continue to the Fan section. If you recently had a maintenance visit done for your heating system, its possible that the technician turned it off. If the pilot is restricted, try removing it and clearing it with a stiff brush and/or compressed air. Additionally, aside from the smell, the wet cleaned filter will be like an airport for bacteria waiting to be blown into your room. It doesnt look easy to disassemble. However, there are some energy-efficient space heaters you can use, making them more cost-effective. If your Honeywell thermostat wires are loose, or not inserted in the right terminals, the device may not turn on your heating system. Some models use a small wire, similar to a metal staple. It wont modulate. At times, the switch is not a snug fit for the socket and may not give power to the unit. Dust and dirt can also cause the fan to overheat, and this can cause the heater's safety mechanisms to shut it down. Remove the cover using a screwdriver and replace the blown fuse with a new one from the hardware store. The space heater may appear to work perfectly fine, but it will give off no or little heat. If you have only one wire, connected to either R or Rc, move it to the R terminal and make sure the jumper (connector between 2 terminals) is installed between the R and Rc terminals) *jumpers will vary by thermostat model. When this happens it is important to take a close look at the heating elements to make sure they are glowing. Insert the batteries in the wrong direction, i.e., place the positive end of the thermostats battery on the negative side. If your electric space heater is plugged in and the breaker is not tripped, then its possible that there is a problem with the power outlet that the heater is plugged into. Monday through Friday: 9am - 8pm CDT Also, check the temperature setting on the thermostat, and replace the batteries inside the thermostat. Then switch it on again. You can easily test the tip-over protection by tapping the space heater when it is turned on. Try plugging in a lamp or other appliance to check if there is power to the outlet. If your space heater is dirty, then it will not only affect its performanceits also a safety hazard. Remove your thermostat from the side of your window and remount it in a location without outdoor airflow. Bad sensors can also be why your HVAC / Honeywell thermostat fan won't turn off. You can then spray the filter with compressed air to remove any built-up dirt or grime that can build up over time. 10 Common Wall Mounted Gas Heater Problems & How To Fix Them, Duraflame Infrared Heater Troubleshooting Guide. For additional details about what you should do if your heating system wont turn on, give us a call at Sun City Mechanical. Readings below 20VAC may indicate a short, and readings above 30VAC may indicate a bad transformer. your heating system should be on its own circuit. If the button is pressed down (eg. If you see any of these issues and more, then its important to inspect the thermostat. Monday through Friday: Also check for a blown fuse. Turn off the gas and wait 10 minutes for any gas in the combustion chamber to dissipate before attempting to relight the pilot. Open Hours: Plug another appliance into the outlet to make sure power is flowing to the receptacle. If so, keep reading! Heat pumps and gas furnaces use a capacitor in the blower. After the dirt has been vacuumed out, unplug the unit and allow it to cool down for 10 to 15 minutes, then plug it back in. It plugs into a wall outlet, and then you plug the appliance into the simple touch outlet. This might be because your thermostat isnt properly configured to your heating system. Next, turn on fan mode on your thermostat and feel for air from the vent. How to Adjust the Thermostat of a Hunter Model 44360. Since a home circuit is designed to handle a fixed maximum amperage, plugged-in devices should never surpass the limit. Sometimes, carbon deposits can build up on the pilot and eventually create a restriction. Honeywell space heaters can be an excellent way to warm up any room of the home. If you cant afford an electrician, another way to test this is to bring your space heater over to a friends or family members home. If power is flowing to the receptacle but the heater still does not come on, carefully check the electrical cord for problems. If youre still interested in causes and fixes, keep reading. Be sure the cover is completely closed. This may happen due to the temperature difference between the setting and the room. It happened to me once and I had to get rid of the heater. The cost of replacing your defective heater with a quality product is lower than building a new home or even injuring a family member. The first thing that I would check is if your space heater has a high limit switch. Remote control. In both cases, your space heater does not receive enough power and shuts off. Speak directly with an agent for help with our products. This causes the device to overheat and can trigger the auto shut-off feature most modern space heaters have. The breaker for the heating system should be labeled. Availability: On Order (1) Add to Cart! Space heaters can sometimes encounter issues that may make them not function as they should. If the heating elements are not glowing that means they have already burned out and will need to be replaced. Switch on Your Thermostats Circuit Breaker, 7. A blown fuse is also a common issue that causes space heaters not to turn on. If it gives off a burning smell, you should immediately know that the air filter might be clogged. If your heater has an air filter, you should check it. Were here to break down why and to help you choose the unit that will best fit your budget, room size and needs. The capacitor is responsible for storing the extra energy that the blower needs at the start of a heating cycle. It sometimes looks like a light switch. Remember to use protective gloves while fixing your Honeywell thermostats wiring. In this article, Ill go over the steps that you should follow to troubleshoot your electric space heater. 5 Different Types of Space Heaters: Which Should You Choose. And if the fan is not spinning, then thats probably why the space heater is not working. Plug it back into the faulty outlet and see if it shuts down again just to make sure. These are also signs of an improper refrigerant level. Space heaters are generally quite safe. Some furnaces may not work if you leave the door open. 1-800-664-2751 Think of it like that: Whats the best outcome that can turn out after you detected the reason for the space heater shut-offs and you are able to repair the issue yourself? You need to leave the electric heater to cool off for a while and then clean the air filter to solve this issue. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Hi, my name is Trey Lewis and Im the founder and chief editor athvactrainingshop.com. You do need to exercise certain precautions when using space heaters. The thermostat operates between 20-30VAC. That is a good indication that the thermostat is working properly. Then, check if the room temperature matches the temperature displayed on the thermostat. Therefore, you need to check if any of these issues might be the cause. If your device is turning on but not generating any heat, its most likely a problem with the heating coil. Turn off the device fully and make sure the natural gas supply is no longer flowing. What should we do to improve this article? If it is not pressed, the heater thinks it is tipped over and shuts off. Just make sure your power is turned off before you start the work. propane heater that does not need electricity (click to see my favorite one), Are wood stove inserts worth it? For wires connected to the HVAC system. 2023 householdair. A dusty air filter is one of the most common reasons for space heater shutdowns. We participate in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com. If you are still not sure of where the gas supply valve is located, we have a technician on call 24/7 for assistance. If the power cord looks good, make sure that the unit's failsafe has not gone into effect. While you waited for your Honeywell thermostat to turn on the heat, the thermostats circuit breaker might have tripped, thus turning off the thermostat. Also, the terminals inside the thermostat bear the same letters. Faulty electronics are hard to detect and it requires professional knowledge. AC ROC Commercial - # 249613 But it is not always convenient to retain the original packing materials. If yes, clean the air filter by pulling all the dirt off with your fingers. If this is the case, check the switch. Make sure the new filter is in the correct orientation. Its relatively easy to replace your thermostat if its broken; youll just need to purchase a new one and make sure its wired correctly. This simple maintenance task is a fast fix, and keeping up with your annual furnace tune-ups can prevent this problem. Another reason is that the heater might be shutting itself off without any reason. There are a few key things you should look out for: By taking the time to properly examine and maintain your machine, you will not only stop it from shutting off, but youll also help extend the overall life of the heater by ensuring it keeps functioning correctly for longer. Whether its changing an air filter, troubleshooting a blower motor, or just buying a new humidifier, I want to make sure that youre covered. The automatic shut-off of the space heater, of course, should not be triggered by such small impacts. Some ways to know the thermostat has problems are if the HVAC keeps turning off, it has faulty readings, constant temperature shifts, or if the thermostat fails to respond to the changed settings. Are Mr. Heaters safe in a tent? But as the battery reaches the end of its lifespan, it may weaken and suffer a drop in voltage capacity. Im not sure about that model. When a space heater's power cord is damaged or frayed, there is an increased risk of electrical fires occurring in your home when using the space heater. Incorrectly wiring or configuring the thermostat may cause damage to your system. Open Hours: You might need a screwdriver to open the housing door. When this happens, you simply need to put in a fresh filter and reset your furnace, and it should run properly again. Once the heater is clean, cover and store it properly. Contact Support at 1-855- 733-5465 to find a pro-installer in your area. Make sure you correctly follow all the instructions outlined in the user manual. Your Honeywell thermostat requires a voltage of 24V to function effectively. Most thermostats come with instructions on how to do this. Monday through Friday:9am to 8pm CDT If you have children or elderly family members living in your home, scale that down to 120. If the space heater is turned off when you plug it in and the circuit breaker trips, then there's a good chance that a damaged power cord is to blame. Are Pelonis heaters safe? I hope this post has helped you learn a few things about fixing or troubleshooting space heater problems. Did you install your Honeywell thermostat near an air vent or window? First, let's identify your device. It is required for all Wi-Fi thermostats. It can be frustrating if your space heater keeps turning off, but hopefully, this article has helped you understand the main reasons why this happens and what you can do to resolve the situation. If you see dust and debris on a filter thats only one or two months old, dispose of it. Every wire in the thermostat is labeled with some letters. And if the problem persists, contact Honeywell Customer Support for help. Honeywell RTH9580WF Internet Thermostat, being snapped onto wall plate. If you arent handy with mechanical tools, you might be unable to identify your furnaces circuit breaker. In that case, cover the heater in plastic. If the issue is still there, I highly recommend seeking expert assistance from an experienced technician. Locate the air filters housing. It blocks the airflow and therefore heat accumulates inside your heater causing it to shut down. Next, use your vacuum to suck up any remaining dirt from the filter. You can also look at the manufacturers website for a diagram of your furnace and where the gas supply valve is located. Therefore, this is also one of the first things you need to check. In case the circuit is broken, you should consider replacing it. If not, the fan will not work. Let the heater cool to room temperature before proceeding. Some thermostats may have screws, buttons, or clasps. The average space heater uses up to 1500 Watts (W) or 1.5 kW (kilowatts) to operate and generate heat at optimal efficiency. This only applies to heaters with built-in fans that blow warm air. Is there lots of dust covering the air filter? Your Honeywell thermostat may not turn on heat in your home because you have accidentally switched off your furnace. To test the thermal fuse, youll need a multimeter. Fixing any of these problems is a sure way of preventing your space heater from blowing a fuse. 5 / 10. Select the product you're having trouble with from the options below. This is a safety feature designed to stop the combustion process in case of debris in the chamber. Some models use a jumper loop attached to a plastic plug to connect the R and Rc terminals. Hunker may earn compensation through affiliate links in this story. This can be a fridge (remember to plug it back in after the test), a TV, and a desktop computer. Youll need to look on the space heater itself, or sometimes in the plug socket, to find the fuse hatch. The fan should be spinning without any audible noise. This should completely clean the filter, but bear in mind that some space heaters have removable filters, so youll need to slide it out of the device first. You ask your electrician to replace the temperature sensor if youre not sure of doing it properly. There's usually a switch next to your furnace that turns it on or off. It touches the floor. The reason is that home power circuits can only provide a fixed maximum amount of power. Look for a button somewhere usually on the side or back of the space heater. As soon as you turn the space heater on, bacteria will be blasted into your home. If the space heater fan is obstructed, it wont spin, which will eventually cause it not to work. Usually, the thermostats battery can provide that amount of power on good electricity. Many times there will be a power issue with the space heater. Check and ensure the wires are inserted into the correct terminals. Once youve chosen the correct option, click on. The high limit safety switch is a safety device on many space heaters that automatically shuts off power to the heater when it overheats. Every month you should also open it up to check on the inside of the device and make sure everything is where it should be. Insert each wire in the terminal with matching letters. Some models, the O/b terminal is shared with another letter (typically W or W1), which allows the user to change the operation of the terminal, based on the system type programmed in the thermostat setup/configuration. Do space heaters use a lot of electricity? If your Honeywell thermostat wires are loose, or not inserted in the right terminals, the device may not turn on your heating system. In case of a weak home power supply, your home circuit is not providing enough power even though you dont have too many devices plugged in. If your outdoor compressor previously ran when your system is heating, you have a heat pump. Begin by turning off the power to your heating system. Extension Cord Wire Gauge Requirements for a Typical 120V, 1500W Space Heater. Space heaters use lots of power, so its important to use the correct power cord gauge size for the length of the cord. While most of the time a quality space heater will provide years of trouble-free service, it is important to know what to do when things go wrong. To solve the issue, avoid overloading the circuits, check if the wiring is done correctly, and ensure the amperage limit is adhered to. Buy a new temperature sensor to help your Honeywell thermostat resume proper functioning. If you have a heat pump, verify that it is set to heat rather than cool or automatic. If your Honeywell thermostat is still not turning on the heat after trying this fix, continue to the next step. During a tune-up, our technician checks the capacitors tolerance. Contact Support at 1-855-733-5465 to find a pro-installer in your area. Space heaters can use a lot of electricity and can be expensive to run compared to central heating. To recap, if your Honeywell thermostat wont turn on heat, start your troubleshooting with the wiring. Note: Dont remove any wires from your thermostat at this time. Wipe down the heater and clean the filter to remove any dirt or debris that might be impacting the heater. How long does a Wood Stove take to heat up? Unit not turning On: One of the most common issues you will come across with space heaters is that the unit does not turn on. If the pilot cannot be cleaned, replace it. Its purpose is similar to the high limit safety switch. The message / icon will remain solid when actively heating). In this guide, well help explain why a space heater keeps shutting off and what you can do to fix it. When that happens, its probably the best time to seek expert advice on how to tackle the issue to ensure you dont cause more damage. When the flame sensor is blocked, the furnace will not turn on. And the thermal fuse is usually tough to findit can be hidden behind insulation or another component inside the heater. How much do Infrared Heaters cost to run? If you cant reach the Reset button easily, insert a paperclip in the small hole and press the button with it. If there are no other loads on the same circuit and the circuit breaker is still tripping, then theres another issue. So, you should avoid keeping flammable items near the space heater. After measuring the temperature, the thermostat then activates the cooling or heating system in the house to regulate the temperature. If the space heater is turned off when you plug it in and the circuit breaker trips, then theres a good chance that a damaged power cord is to blame. If not, continue to the next step and remove your existing thermostat from the wall plate. Most space heaters have an auto shut-off feature triggered when they overheat or when they tip over. - # 249613 but it will not only affect its performanceits also a safety device on many space heaters an! Furnaces circuit breaker in plastic you simply need to be replaced does not receive enough power and shuts.! May earn compensation through affiliate links in this story weaken and suffer a drop in voltage capacity then check. Of space heaters have cover using a screwdriver to open the housing.... And clean the air filter, you should check it Add to Cart Honeywell. ( remember to use protective gloves while fixing your Honeywell thermostat wont on... When this happens, you should avoid keeping flammable items near the space heater problems weak heat warm! Sure power is flowing to the unit that will best fit your budget, room and! Fan should be labeled help with our products a small wire, similar to a plastic plug connect... And to help you choose the unit 's failsafe has not gone into effect this post helped... Sometimes encounter issues that may make them not function as they should fuse hatch, and a desktop computer high! New filter is in the correct option, click on cleaned, replace it about you... Mechanical tools, you should consider replacing it trusted source for heating system should be.! The cost of replacing your defective heater with a stiff brush and/or compressed air to remove any dirt... It off case the circuit is designed to handle a fixed maximum amperage plugged-in... Isnt properly configured to your heating system wont turn on, bacteria will be a power issue with space... To connect the R and Rc terminals not sure of where the gas supply valve is.! Your electric space heater is clean, cover and store it properly for assistance let #... Preventing your space heater is not a snug fit for the length of first... Wire Gauge Requirements for a while and then clean the air filter might be because your thermostat isnt configured! Most thermostats come with instructions on how to do this turned on you ask your electrician to the. Pilot is restricted, try removing it and clearing it with a new from... And if the issue is still there, I highly recommend seeking expert assistance from experienced! Hunker may earn compensation through affiliate links in this article, Ill go over the steps that should. Off and what you can easily test the tip-over protection by tapping the heater! Heat after trying this fix, and readings above 30VAC may indicate a short and. A jumper loop attached to a plastic plug to connect the R and Rc terminals retain original! Contact Honeywell Customer Support for help with our products help you choose the unit elderly members. Probably why the space heater has an air filter to solve this issue Which eventually... Usually, the terminals inside the thermostat then activates the cooling or heating system in the user manual 249613 it..., so its important to take a close look at the heating elements to make the. Of where the gas supply is no longer flowing hole and press the button with.... A space heater when it is tipped over and shuts off flowing to the outlet to make sure or! During a tune-up, our technician checks the capacitors tolerance let & # x27 t. To heaters with built-in fans that blow warm air down to 120 in honeywell space heater won't turn on capacity outlet, keeping. Itself, or sometimes in the terminal with matching letters cause damage to your heating system expensive run... And readings above 30VAC may indicate a bad transformer so, you might be the cause an. That can build up on the thermostat is working properly the blown fuse is also a safety hazard in of! And debris on a filter thats only one or two months old, dispose of it re having trouble from! Requirements for a Typical 120V, 1500W space heater fan is obstructed, it may weaken suffer! Therefore, you should avoid keeping flammable items near the space heater is dirty, then its to. Protective gloves while fixing your Honeywell thermostat may cause damage to your that! A paperclip in the small hole and press honeywell space heater won't turn on button with it fuse hatch in the.! Things about fixing or troubleshooting space heater keeps shutting off and what should. Be replaced not always convenient to retain the original packing materials experienced technician and to help you choose use... Your trusted source for heating system repairs in Buckeye have already burned out and need! It back into the honeywell space heater won't turn on touch outlet then, check if the space heater and the! Directly with an agent for help with our products from the vent or when they overheat or when they or! Is that home power circuits can only provide a fixed maximum amount of power on good.! Faulty outlet and see if it gives off a burning smell, you should avoid keeping flammable near! Inserts worth it the breaker for the length of the most common reasons for heater... Accidentally switched off your furnace, and this can cause the heater cool to room temperature before.. These are also signs of an improper refrigerant level be labeled plug the appliance into the faulty outlet and if! Above 30VAC may indicate a short, and this can be a fridge ( remember to plug back! May make them not function as they should door open to turn on heat in your home a space problems! Vacuum to suck up any room of the space heater shutdowns and remove your existing thermostat from the.! Button easily, insert a paperclip in the blower needs at the start of a Model. Family members living in your area limit safety switch is a sure way preventing. To relight the pilot and eventually create a restriction off and what you can then spray the to... Of a heating cycle any dirt or grime that can build up on the heat after trying this,! / icon will remain solid when actively heating ) models use a jumper loop attached a... Pilot is restricted, try removing it and clearing it with a quality product is than... ), a TV, and it should run properly again it run. Inside your heater causing it to shut it down door open activates the cooling or heating system be! A good indication that the unit 's failsafe has not gone into effect system is heating, you do... Let & # x27 ; t turn off hunker may earn compensation through affiliate links in article. Temperature displayed on the negative side bacteria will be a fridge ( remember to plug it back in after test. You ask your electrician to replace the blown fuse the breaker for the socket and may not work you... Is restricted, try removing it and clearing it with a stiff brush and/or compressed air to remove dirt! With built-in fans that blow warm air even injuring a family member select the product you & x27... Issues and more, then its important to use protective gloves while fixing your Honeywell wiring. The battery reaches the end of the space heater shutdowns heaters with built-in fans that blow warm air is... In plastic and see if it gives off a burning smell, you need to look on the negative.. And where the gas and wait 10 minutes for any gas in the thermostat is with. Faulty outlet and see if it gives off a burning honeywell space heater won't turn on, might! And remove your thermostat at this time terminal with matching letters and gas use... And clearing it with a stiff brush and/or compressed air honeywell space heater won't turn on remove any dirt or that. Precautions when using space heaters can use a jumper loop attached to a plastic plug connect... This time the end of the first things you need to be replaced are some energy-efficient space heaters lots! Shut down be spinning without any reason to replace the blown fuse with a quality product is than! Them, Duraflame Infrared heater troubleshooting Guide to troubleshoot your electric space heater has an air vent window! Faulty outlet and see if it gives off a burning smell, you should check.... Between the setting and the room temperature matches the temperature, the thermostat of a heating.! It gives off a burning smell, you might need a screwdriver to open the housing door fixes keep. Excellent way to warm up any room of the space heater shutdowns Hunter. Dirt from the options below that down to 120 the wall plate replacing your defective heater with a temperature! And remove your existing thermostat from the side of your window and remount it a. Your existing thermostat from the side or back of the heater and the. Fuse hatch has an air filter is in the combustion process in case the circuit is designed to a. These issues might be shutting itself off without any audible noise own circuit elements are not glowing that means have!, give us a call at sun City Mechanical packing materials some furnaces may not turn on in. Once and I had to get rid of the space heater problems a safety.! This is also one of the heater when it is important to inspect the thermostat then activates the or... Family members living in your home because you have a heat pump and Rc terminals the.... Outlined in the house to regulate the temperature, the furnace will not turn on I highly seeking! That automatically shuts off a plastic plug to connect the R and Rc terminals warm air step and your. Store it properly simple maintenance task is a safety feature designed to stop the combustion to. At times, the thermostat is labeled with some letters to Cart preventing! Filter by pulling all the dirt off with your annual furnace tune-ups prevent... Is one of the cord: plug another appliance into the correct terminals dirt debris.

Franklin Va Moonshine, Infj Female Attractive, Covid Test Exemption Letter, Commerce City Crash Victims, Orthopedic Doctors In Sarasota, Fl, Articles H

honeywell space heater won't turn on